Skip to main navigation Skip to main content Skip to page footer

Power cables assembled to SEW

Shielded continuous bending hi-flex cables

Properties of the cables

  • UV-resistant
  • CFC-free
  • Minimum bend radius 7.5 x Ø
  • Halogen-free
  • Flame-retardant

Approvals:
cURus,
based on VDE,
REACH/RoHS II

Power basic cables assembled to SEW

SEW
Assembling

Core number x
Cross-section
[mm2]

max. ∅
[mm]

Connection
Motor

Connection
Controler

Cable weight
[kg/m]

Copper weight
[kg/m]

0590 4803

(4 G 4²)

12,3

1 ÜWM

open end

0,273

0,195

0590 6245

(4 G 1,5²)

9,5

1 ÜWM

open end

0,136

0,080

0590 6253

(4 G 2,5²)

11,0

1 ÜWM

open end

0,198

0,120

1335 0293

(4 G 6²)

14,9

1,5 ÜWM

open end

0,393

0,296

1335 0307

(4 G 10²)

18,2

1,5 ÜWM

open end

0,616

0,445

1335 0315

(4 G 16²)

22,3

1,5 ÜWM

open end

0,949

0,730

Additional types upon request.

Varying parameters possible.
ÜWM = coupling nut with full thread

Power basic cables assembled to SEW

SEW
Assembling

Core number x
Cross-section
[mm2]

max. ∅
[mm]

Connection
Motor

Connection
Controler

Cable weight
[kg/m]

Copper weight
[kg/m]

0590 4846

4 G 4 + (3 x 1.0) C

15.3

1 ÜWM

open end

0.417

0.262

0590 6318

4 G 1.5 + (3 x 1.0) C

12.3

1 ÜWM

open end

0.247

0.137

0590 6326

4 G 2.5 + (3 x 1.0) C

13.4

1 ÜWM

open end

0.318

0.190

1332 2139

(4 G 2.5² + ( 2 x 1²))

13.1

1 ÜWM

open end

0.274

0.180

1332 2147

(4 G 4² + (2 x 1²))

14.9

1 ÜWM

open end

0.378

0.260

1332 4853

(4 G 1.5² + (2 x 1²))

11.7

1 ÜWM

open end

0.212

0.140

1333 1221

(4 G 1.5² + (2 x 1²))

11.7

1 ÜWM

open end

0.212

0.140

1333 2155

(4 G 2.5² + (2 x 1²))

13.1

1 ÜWM

open end

0.274

0.180

1333 2163

(4 G 4² + (2 x 1²))

14.9

1 ÜWM

open end

0.378

0.260

1335 0153

4 G 6 + (3 x 1.5) C

17.5

1.5 ÜWM

open end

0.579

0.362

1335 0234

4 G 6 + (3 x 1.5) C

17.5

1.5 ÜWM

open end

0.579

0.362

1335 4302

4 G 1.5 + (3 x 1.0) C

12.3

1 ÜWM

open end

0.247

0.137

1335 4329

4 G 4 + (3 x 1.0) C

15.3

1 ÜWM

open end

0.417

0.262

1335 4388

4 G 1.5 + (3 x 1.0) C

12.3

1 ÜWM

open end

0.247

0.137

1335 4396

4 G 2.5 + (3 x 1.0) C

13.4

1 ÜWM

open end

0.318

0.190

1342 1603

4 G 4 + (3 x 1.0) C

15.3

1 ÜWM

open end

0.417

0.262

Additional types upon request.

Varying parameters possible.
ÜWM = coupling nut with full thread

Power basic cables assembled to SEW

SEW
Assembling

Core number x
Cross-section
[mm2]

max. ∅
[mm]

Connection
Motor

Connection
Controler

Cable weight
[kg/m]

Copper weight
[kg/m]

0199 1809

(4 G 1.5²)

9.5

C148

open end

0.136

0.080

0199 1825

(4 G 2.5²)

11

C148

open end

0.198

0.120

0199 1841

(4 G 4²)

12.3

C148

open end

0.273

0.195

0199 1868

(4 G 6²)

14.9

C148

open end

0.393

0.296

0199 1884

(4 G 10²)

18.2

C148

open end

0.616

0.445

1333 1140

(4 G 1.5²)

9.5

C148

open end

0.136

0.080

1333 1159

(4 G 2.5²)

11

C148

open end

0.198

0.120

Additional types upon request.

Varying parameters possible.

Power basic cables assembled to SEW

SEW
Assembling

Core number x
Cross-section
[mm2]

max. ∅
[mm]

Connection
Motor

Connection
Controler

Cable weight
[kg/m]

Copper weight
[kg/m]

0199 19494 G 4 + (3 x 1.0) C15.3C148open end0.4170.262
0199 19654 G 6 + (3 x 1.5) C17.5C148open end0.3620.362
1333 11674 G 1.5 + (3 x 1.0) C12.3C148open end0.1370.137
1333 11754 G 2.5 + (3 x 1.0) C13.4C148open end0.1900.190

Additional types upon request.

Varying parameters possible.

Power extension cables assembled to SEW

SEW
Assembling

Core number x
Cross-section
[mm2]

max. ∅
[mm]

Connection
Motor

Connection
Controler

Cable weight
[kg/m]

Copper weight
[kg/m]

1333 2457

(4 G 1.5²)

9.5

1 ÜWM

1 ÜWM

0.136

0.080

1333 2465

(4 G 2.5²)

11

1 ÜWM

1 ÜWM

0.198

0.120

1333 2473

(4 G 4²)

12.3

1 ÜWM

1 ÜWM

0.273

0.195

1333 2481

4 G 1.5 + (3 x 1.0) C

12.3

1 ÜWM

1 ÜWM

0.247

0.137

1335 0021

(4 G 6²)

14.9

1.5 ÜWM

1.5 ÜWM

0.393

0.296

1335 0048

(4 G 10²)

18.2

1.5 ÜWM

1.5 ÜWM

0.616

0.445

1335 0056

(4 G 16²)

22.3

1.5 ÜWM

1.5 ÜWM

0.949

0.730

1335 0099

4 G 6 + (3 x 1.5) C

17.5

1.5 ÜWM

1.5 ÜWM

0.579

0.362

1335 4221

4 G 1.5 + (3 x 1.0) C

12.3

1 ÜWM

1 ÜWM

0.247

0.137

1335 4248

4 G 2.5 + (3 x 1.0) C

13.4

1 ÜWM

1 ÜWM

0.318

0.190

1335 4337

4 G 4 + (3 x 1.0) C

15.3

1 ÜWM

1 ÜWM

0.417

0.262

Additional types upon request.

Varying parameters possible.
ÜWM = coupling nut with full thread

Power extension cables assembled to SEW

SEW
Assembling

Core number x
Cross-section
[mm2]

max. ∅
[mm]

Connection
Motor

Connection
Controler

Cable weight
[kg/m]

Copper weight
[kg/m]

0199 2007

4 G 1.5 + (3 x 1.0) C

12.3

C148

C148

0.247

0.137

0199 204X

4 G 4 + (3 x 1.0) C

15.3

C148

C148

0.417

0.262

0199 2066

4 G 6 + (3 x 1.5) C

17.5

C148

C148

0.579

0.362

0199 5545

(4 G 4²)

12.3

C148

C148

0.273

0.195

0199 5561

(4 G 6²)

14.9

C148

C148

0.393

0.296

0199 5588

(4 G 10²)

18.2

C148

C148

0.616

0.445

1333 1183

(4 G 1.5²)

9.5

C148

C148

0.136

0.080

1333 1191

(4 G 2.5²)

11

C148

C148

0.198

0.120

1333 1205

4 G 1.5 + (3 x 1.0) C

12.3

C148

C148

0.247

0.137

1333 1213

4 G 2.5 + (3 x 1.0) C

13.4

C148

C148

0.318

0.190

       

Additional types upon request.

Varying parameters possible.

Matching with

Cable carriers

Whether cable carriers made of steel, plastic or hybrid product – at KABELSCHLEPP® the conditions of your application determine the material. After assessing your application parameters we will recommend a product that represents the optimum in terms of load capacity, durability and longevity. The material itself is secondary. You can choose from our product portfolio of thousands of types between standard widths and individual millimeter grids – just as required.

Ready-to-connect cable carrier systems – TOTALTRAX®

From pre-assembled cables to complex, ready-to-connect systems, from lot size 1 to series – worldwide thousands of KABELSCHLEPP® systems are reliably in use. The benefits of TOTALTRAX® systems are obvious: just one person of contact, one order number, delivery just-in-time to your production facility, shortest downtimes thanks to plug&play installation.

Accessories – Strain relief devices

For optimum placement with dynamic use of cables.